Hanging protocol

CT chest, with prior

Applies when a chest CT is opened and a comparable prior exists within 24 months. Everything below is what the reader sees before touching anything.

Layout
124

There is no three-pane option. A three-up layout leaves one quadrant empty on every display we support, and an empty quadrant on a diagnostic screen is a place for the eye to go that has no information in it.

Opens with
WindowLung 1500 / −600
Slice thickness10 mm
Linked scrollon
Linked zoomoff
Corner overlayfull
Series order
1Axial lung, currentSER 3
2Axial lung, priorSER 3
3Axial soft tissue, currentSER 7
4Axial soft tissue, priorSER 7